Article: E1.2N-A/E 1200 Ekip Dip LSI 3p F F

Article: E1.2N-A/E 1200 Ekip Dip LSI 3p F F
E1.2N-A/E 1200 Ekip Dip LSI 3p F F
We find the right product
for you
Official reseller
Expert engineering support
Configuration
General Information | |
Extended Product Type: | E1.2N-A/E 1200 Ekip Dip LSI 3p F F |
Product ID: | 1SDA114840R1 |
EAN: | 8056221054300 |
Catalog Description: | E1.2N-A/E 1200 Ekip Dip LSI 3p F F |
Long Description: | C.BREAKER SACE EMAX2 E1.2N-A 1200 UL FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP/DIP-LSI R 1200 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED |
| |
EAN: | 8056221054300 |
Minimum Order Quantity: | 1 piece |
Customs Tariff Number: | 85362090 |
| |
Product Net Width: | 214 mm |
Product Net Height: | 295 mm |
Product Net Depth / Length: | 184 mm |
Product Net Weight: | 11 kg |
| |
Package Level 1 Units: | 1 piece |
Package Level 1 Width: | 365 mm |
Package Level 1 Height: | 350 mm |
Package Level 1 Depth / Length: | 330 mm |
Package Level 1 Gross Weight: | 16 kg |
Package Level 1 EAN: | 8056221054300 |
Technical UL/CSA | |
Ampere Rating UL/CSA: | 1200 A |
Interrupting Rating acc. to UL1066: | (600 V AC) 35 kA |
| |
Current Type: | AC |
Electrical Durability: | Ue = 508 ... 635 V 6500 cycle |
30 cycles per hour | |
Mechanical Durability: | 20000 cycle |
60 cycles per hour | |
Number of Poles: | 3 |
Power Loss: | 125 W |
Product Main Type: | SACE Emax 2 |
Product Name: | Air Circuit Breaker |
Product Type: | Air Circuit Breaker |
Rated Current (In): | 1200 A |
Rated Voltage (Ur): | 800 V |
Rated Insulation Voltage (Ui): | 800 V |
Rated Operational Voltage: | 800 V |
Rated Service Short-Circuit Breaking Capacity (Ics): | (1000 V AC) 50 kA |
Rated Short-time Withstand Current (Icw): | for 1 s 35 kA |
for 3 s 30 kA | |
Rated Uninterrupted Current (Iu): | 1200 A |
Release: | Ekip Dip LSI |
Release Type: | EL |
Short-Circuit Performance Level: | N |
Standards: | UL |
IEC | |
Sub-type: | E1.2 |
Version: | F |
| |
Data Sheet, Technical Information: | 1SXU200040C0201 |
Declaration of Conformity - CE: | 1SDL000165R0019 |
Instructions and Manuals: | 1SDH000999R0002 |
| |
ETIM 4: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 5: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 6: | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 7: | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
WEEE Category: | 4. Large Equipment (Any External Dimension More Than 50 cm) |